Fault Indicators
Zone
Indicator
Fault Description Hold Down
Button
Zone
Indicator
Fault Condition
1 System Fault 1 1
2
3
4
5
7
8
9
Battery Fail
Date and Time
RF Receiver Fail
Output 1 to 3 Fail
Telephone Line Fail
Power Supply Fail
Tamper
RF Repeater Fail
2 RF Low Battery 2 1 to 16 Zones 1 to 16 RF Low Battery
3 Zone Tamper Alarm 3 1 to 16 Zones 1 to 16 Tamper Alarm
4 Sensor Watch Fault 4 1 to 16 Zones 1 to 16 Sensor Watch Fail
5 RF Sensor Watch 5 1 to 16 Zones 1 to 16 RF Sensor Watch Fail
6 Communication Fail 6 1
2
3
4
Receiver 1 Fail
Receiver 2 Fail
IP Module 1 Fail
IP Module 2 Fail
7 Output and
Codepad Fail
7 2
3 to 6
Output Expander Fail
Codepad Fail
8 Keyfob Low Battery 8 1 Keyfob Low Battery
Table 5.4: Fault Indicators
Fault Descriptions
1 System Fault
A system fault only displays when any of the following faults occur. After entering Fault
Analysis Mode, press and hold the [1] key to determine which of the following faults occurred.
Low Battery Fault – A low battery fault registers when the system detects a low capacity
back-up battery. The system automatically performs a battery test every four hours and every
time you arm the system.
Date and Time – The date and time fault registers every time the system is powered down.
Refer to Date and Time, page 21 to program the date and time.
RF Receiver Fail – The RF receiver fault registers once the system detects that the wireless
receiver unit is disconnected, tampered or jammed.
Output 1 to 3 Fail – This fault registers when the system detects any output is disconnected.
This fault clears once any output is reconnected. Your installer must program the system for
this feature to operate.
Telephone Line Fail – A telephone line fault registers when the system detects that the
telephone line is disconnected from the control panel. Your installer must program the system
for this feature to operate.
Power Supply Fail – This fault occurs when AUX power supplies fails, +12V power fails, or
SDI2 Bus power fails. Contact your installer as soon as this fault displays.
Tamper – This fault occurs when the system detects the control panel is tampered.
5.6.1
20 en | Operation with ICON LCD Codepad Control Panel
2014.05 | 01 | F01U298028 User's Guide Bosch Security Systems, Inc.