Audible Indications
Below table defines the audible indicators given out by the codepad buzzer.
Audible Indicator Definition
One short beep A button was pressed on the codepad, or Exit Time ended
when armed in STAY Mode 1 or STAY Mode 2.
Two short beeps The system accepted your code.
Three short beeps The requested function was executed.
One long beep Indicates the last 10 seconds of Exit Time when armed in AWAY
Mode, or the requested operation was denied or aborted.
Indicates codepad panic/fire/medical alarm operation.
One beep every sec Walk Test Mode is currently active.
One short beep every min There is a system fault waiting to be acknowledged.
One beep every 4 sec. During Auto Arming Pre-Alert Time, the warning before
automatic arming takes place.
One beep every 2 sec. During Exit Time when armed in AWAY Mode.
Table 3.1: Audible Indicators
3.4
Control Panel Codepad Introduction | en 9
Bosch Security Systems, Inc. User's Guide 2014.05 | 01 | F01U298028