10.1 Power consumption
230 V/50 Hz operation
I
supply
S
supply
P
supply
P
out
BTU/h
Standby 0.14A 33.0VA 1.9W 0.0W 6.5
Idle (no audio) 0.20A 47.0VA 19.5W 0.0W 66.5
Announcement (-10 dB) 0.88A 202VA 175W 100W 255.8
Alert (-3 dB) 3.35A 772VA 745W 500W 835.5
120 V/60 Hz operation
I
supply
S
supply
P
supply
P
out
BTU/h
Standby 0.09A 9.0VA 1.3W 0.0W 4.4
Idle (no audio) 0.27A 29.0VA 17.3W 0.0W 59.0
Announcement (-10 dB) 1.6A 189VA 175W 100W 255.8
Alert (-3 dB) 6.9A 824VA 800W 500W 1023
24 V DC operation
I
supply
S
supply
P
supply
P
out
BTU/h
Standby 0.06A - 1.4W 0.0W 4.8
Idle (no audio) 0.65A - 15.6W 0.0W 53
Announcement (-10 dB) 7.0A - 168W 100W 232
Alert (-3 dB) 32.5A - 780W 500W 938
Description of table columns:
I
supply
= RMS current drawn from mains (or DC supply)
S
supply
= apparent power drawn from the mains line
P
supply
= reactive power drawn from mains (or DC supply)
P
out
= NF output power provided to the speaker lines
P
loss
or BTU/h = thermal loss