EasyManua.ls Logo

Bosch PAVIRO PVA-2P500 - System Overview; Front Panel

Bosch PAVIRO PVA-2P500
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PAVIRO Amplifier System overview | en 7
Bosch Security Systems, B.V.
User manual
2023-03 | 08 | F01U306898
3 System overview
3.1 Front panel
Number Symbol Element Description
1 Signal clip
indicator light
Indicates the signal level of the amplifier channel:
Green = The output signal is 18 dB below clip
level
Yellow = The output signal is clipping or the
integrated limiter of the amplifier is limiting the
output signal.
2 Combined fault
warning indicator
light
This indicator lights up yellow when a fault has
occurred in the device. The types of faults to be
displayed via this indicator are configured in IRIS-
Net. Please refer to section
Operation, page 22
.
3 Recessed button The button is protected to prevent it from being
pressed accidentally. Use a pointed object (such as
a ballpoint pen) to press the button.
This button has the following functions if the CAN
address of the device is not set to 00:
Find function: If the find function of the device
is activated, press this button to deactivate the
indicators.
Displaying the CAN baud rate: Press this button
for at least one second. Please refer to section
Displaying the CAN baud rate, page 21
.
LED test: Press this button for at least three
seconds to activate the LED test. All indicators
at the front panel light up as long as the button
is pressed.
This button has the following functions if the CAN
address of the device is set to 00 (stand-alone
mode):