6.8 DCF77
The top half of the control port has an input for the radio receiver of the DCF77 signal.
Observe the delivered documentation when connecting a 3
rd
party DCF receiver to the
controller.
Recommended connecting cable: shielded flexible stranded wire, LiY, 0.5 mm².
6.9 Ready relay
The lower half of the control port has a potential-free READY changeover contact. This
changeover contact signals to other devices that the controller is ready for operation or
indicates faults in the system. The following table shows the possible statuses of the ready
contact.
Recommended connecting cable: shielded flexible stranded wire, LiY, 0.5 mm².
Status Switch position Description
Ready for operation (=
ready)
The voltage supply is functioning,
the boot process of the device has
completed, and there are no faults
in the system. The relay has been
activated.
Not ready The voltage supply is off/interrupted
or the boot process of the device
has not yet completed, or there is a
fault in the system. The relay has
dropped/is without power.
Table6.6: READY contact