EasyManua.ls Logo

Bosch Plena LBB1930/20 - Page 10

Bosch Plena LBB1930/20
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Apparatus
delivered
connectored
for 230V~
Inp ut 1 Priori ty
Loo pthrou gh 1
Inpu t 2P rogra m
Loo pthrou gh 2
Inpu t 1P riori ty
2.. .24V- Inp ut 1
0V- In put 2
Inpu t 2E nable
2.. 24V- Enab le
0V- Mu te
100V
0
Sla ve Input 10 0V
+
+
-
-
Rated input
Power : 1600VA
OOn
Main Power
BatteryInput
Fault Relays' Output
NO COM NC
OOn
NO COM NC NO COM NC
Battery
Detection
Pilot-tone
Detector
InputInput
Input Output
Input 2-Progr
Power
amInput 1-Pr iority
Input 1
Pr iority
Slave Input
100V
Input 2
Enable
100V 0
2..24V
Defaul t O
GND 2..24V
Defaul t On
GND
24V DC In
Priority Only No Priority
100V 100V 0V0V
Priority Controlled Output
100V 7 0V0 0 8
Direct O ut put
100V
0
70V
0
8ohm
100V /70V
Sele ction (1 2A)
Prio rity Onl y
0
0
No Prio rity
Prio rity
F701
F702
141517181920 16
1 2 3 5 64
7
9
12
11
10
8
Figure 5.3: LBB 1938/x0
Note that slight deviations from the rear panel layout shown may occur.
1. Priority line input 1 (XLR/balanced)
2. Level control input 1
3. Priority loopthrough output 1 (XLR/balanced)
4. Program line input 2 (XLR/balanced)
5. Level control input 2
6. Program loopthrough output 2 (XLR/balanced)
7. Priority controlled loudspeaker output terminals
8. 24 Vdc power supply terminals
9. Earth connection screw
10. Mains fuse (T10A)
11. Mains connector (3-pole)
12. ON - OFF switch
13. Voltageselector (Not on LBB 1938/x0)
14. Loudspeaker direct output terminals
15. Battery detection
16. Fault relay output
17. Pilot-Tone detection
18. 100 V slave input terminals
19. Input 2 enable control terminals
20. Input 1 priority control terminals
10
en | Connection and indicators Plena Power Amplifiers
2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.