EasyManua.ls Logo

Bosch Plena Power Amplifier - Priority Input and Control Terminals

Bosch Plena Power Amplifier
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bosch Security Systems | 2006-11 | 9922 141 50751en
Plena Power Amplifier | Installation and User Instructions | Amplifiers en | 14
3.5.3 Connecting the priority input and
using the control terminals
The power amplifier is provided with a balanced
priority input (Input 1-Priority) to connect to another
pre-amplifier or mixer.
Apply a control voltage of 2...24 V to the input 1
priority control terminals (20) to switch ON the priority
input (1) and mute the program input (4). A local music
source can be connected to the program input and a
remote emergency system to the priority input. The
emergency source must be able to supply the 2…24 V
control voltage to override the local music source. The
program input can be remotely controlled by using a
switch that is connected to the input 2 enable control
terminals (19).
Application example for use of the power amplifier
control terminals (see figure 3.8)
You can use up to 6 power amplifiers in combination
with the Plena LBB1925/10 System Pre-amplifier to
build a powerful multi-zone sound system. Zone
switching of BGM and calls is done via the LBB1925/10
zone relays in combination with the power amplifier
control terminals. The LBB1925/10 controls the
background music by distributing 24 Vdc via the music
zone relays to the input 2 enable control terminals (19).
The LBB1925/10 controls the calls by distributing 24
Vdc via the call zone relays to the input 1 priority
control terminals (20). Each power amplifier serves one
loudspeaker zone. Each zone can be OFF, or receive
music or a call.
figure 3.8: Priority input and control terminals
Priority Only No Priority
100 V 0 1 00 V 0
Priority Controlled Output
Off On
24V DCIn
Apparatus delivered
connectored for 230V~
Main Power
BatteryInput
Fault Relays' Output
NOCOM NC
Off On
NOCOM NC NO COM NC
Input1Priority
Loopthrough1
Input2Program
Loopthrough2
Input1Priority
2...24V - Input 1
0V- Input 2
Input2Enable
2..24V- E nable
0V- Mute
100V
0
Slav eI nput 100V
+
+
-
-
100V
0
70V
0
8ohm
100V/70V
Selection(12A)
PriorityOnly
0
0
NoPriority
Priority
F701
F702
Battery
Power
Detection
Pilot-tone
Detector
230V~ 240V~
Design& Quality
TheNe therlands
LBB1938/10
NL-4827HG-10
Plena480W PowerAmplifier
Max.o utput power 720W
Ratedoutput power 180W
230V~,50/60Hz
S/N.
8900 193 81001
A035413
Madein China
N663
Rated input
Power : 1600VA
Input1
Priority
SlaveInput
100V
Input2
Enable
100V 0
100V 70V008
Direct O utput
InputInput
Input2-P rogramInput1-P riority
2..24V
DefaultOff
GND 2..24V
DefaultOn
GND
Priority Only No Priority
100 V 0 1 00 V 0
Priority Controlled Output
Off On
24V DCIn
Apparatus delivered
connectored for 230V~
Main Power
BatteryInput
Fault Relays' Output
NOCOM NC
Off On
NOCOM NC NO COM NC
Input1Priority
Loopthrough1
Input2Program
Loopthrough2
Input1Priority
2...24V-Input1
0V- Input 2
Input2Enable
2..24V-Enable
0V- Mute
100V
0
Slav eI nput 100V
+
+
-
-
100V
0
70V
0
8ohm
100V/70V
Selection(12A)
PriorityOnly
0
0
NoPriority
Priority
F701
F702
Battery
Power
Detection
Pilot-tone
Detector
230V~ 240V~
Design& Quality
TheNetherlands
LBB1938/10
NL-4827HG-10
Plena480W PowerAmplifier
Max. output power 720W
Ratedoutput power 180W
230V~,50/60Hz
S/N.
8900 193 81001
A035413
Madein China
N663
Rated input
Power : 1600VA
Input1
Priority
SlaveInput
100V
Input2
Enable
100V 0
100V 70V008
Direct O utput
InputInput
Input2-P rogramInput1-P riority
2..24V
Defa ult O ff
GND 2..24V
DefaultOn
GND
3
Tel/EMG
0
L
R
1-
45
/Line
/Line
Trigger 1 Trigger 2
PCAudoln
1. Audio+
2.0V
3.Audio-
4.24Vd.c.
5. Allcall
6.Data-
7.Data+
8.Chs.GND
RS232
CD Aux
MasterOut Out
100V 0100V 0 100V 0 100V 0
100 V
115V 230V
Rated Input
Power : 50VA
T0.5L 250V
Apparatus delivered
connected for 230V-
0 100V 0 100V 0 100V 0
+24V- +24V-
This apparatus must be earthed
Warning
3
7
8
6
1
5
2
4
3 1
5
2
4
LBB1925/10
890019251005
115/230V~,50/60Hz
No.
3
1
+
-
2
GND
3
2
+
-
1
GND
LBB1925/10
1 4
20
19
20
19
Zone 1 output Zone 2 output
to next zones
1 4

Related product manuals