English | 17
Bluetooth
®
activated, connection not established
Bluetooth
®
activated, connection established
(b)
Battery indicator
(c)
Measured value lines
(d)
Result line
(e)
Laser switched on
(f)
Reference level of measurement
(g)
Measuring function display
(h) Error display "Error"
Technical data
Digital laser measure PLR 30 C PLR 40 C
Article number
3603F721.. 3603F723..
Measuring range
A)
0.05−30m 0.05−40m
Measuring accuracy
B)
±2.0mm ±2.0mm
Operating temperature –10°C to +40°C –10°C to +40°C
Storage temperature –20°C to +70°C –20°C to +70°C
Relative air humidity max. 90% 90%
Max. altitude 2000m 2000m
Pollution degree according to IEC61010-1 2
C)
2
C)
Laser class 2 2
Laser type 635nm, <1mW 635nm, <1mW
Divergence of the laser beam <1.5mrad (full
angle)
<1.5mrad (full
angle)
Automatic switch-off after approx.
– Laser 20s 20s
– Measuring tool (without measurement)
D)
5min 5min
– Bluetooth® (when inactive) 3min 3min
Batteries 2×1.5V LR03
(AAA)
2×1.5V LR03
(AAA)
Data transmission
Bosch Power Tools 1 609 92A 6KX | (24.06.2021)