15 Technical data
Tab. 10
Designation LTS350D LTE350D
Order number 0 608 750 125 0 608 750 126
Input voltages From the supply module
Intermediate circuit voltage 220 V
DC
to 330 V
DC
Control voltage + 24 V / – 24 V / 5 V
Output voltage 3-phase, 0-230 V
AC
Output frequency 0 Hz to 1000 Hz
Rated current/peak current Depending on the connected motor, max. 12 A / 50 A
Maximum line length to motor 100 m
Interference suppression EN 55011 class A (industrial area)
Interference immunity IEC 1000-4 part 2 to part 6 severity level 4
Permissible ambient temperature 0 to 55 °C with fan
Admissible relative humidity during operation 20 % - 90 % non-condensing
Admissible storage temperature –20 °C to 70 °C
Admissible relative storage humidity 20 - 95 %
Protection class Protection class I
Protection type IP20 (protection against accidental contacts) when
installed
Dimensions (W x H x D) 46 mm x 271 mm x 285 mm
Weight 2.7 kg