28/48 Analog amplifier RA | Installation
BoschRexrothAG, RE95230-B/2021-12-01
4� Slide the locking pieces onto both sides of the contact carrier.
Fig� 17: Locking pieces
5� Push the handle shell to the insulation hose end.
Hang the latch of the contact carrier on the side of contacts 1 and 14 in the
internal latch of the handle shell on the side of the cable entry opening.
The insulation hose end must reach into the handle shell by approx.1 to
1.5cm via the terminal area of the cable clamp.
The contact carrier must still hang out on the opposite side of the cable entry
opening (no tension on the wires)
approx.1 - 1.5cm
Contact carrier hanging out
Clamping collar
Latches
Fig� 18: Bringing contact carrier into position
6� Screw on the clamping collar with the corresponding screws.
Tightening torque 0.9 – 1.1 Nm
If the clamping of the insulation hose (e.g.with few wires) is too low,
adhesive tape has to be applied in the terminal area.