26/48 Bosch Rexroth AG VT-HNC100...3X | RE 30139-B/12.14
Assembly
Table 7: Pin assignment
VT-HNC100 Compact
HNC100...3X shield system:
Fig. 8: Breakout cable with micro Combicon connector, 8-pole
1 Shield clamp:
The open end of the assembled breakout cable is connected with the terminal
block.
Using a shield clamp which is adjusted to the shield strip, the pushed back
cable shield is pushed extensively to the potential of the control cabinet rear
Slot X2A1 AIO (analog) Slot 1 X8M1 Encoder
Incremental SSI
Pin 1 Vin 1 + Pin 1 – B
Pin 2 Vin 1 – Pin 2 + CLK
Pin 3 Vin 2 – Pin 3 + R
Pin 4 Vin 2 – Pin 4 – R
Pin 5 Cin 1 + Pin 5 + A
Pin 6 Cin 1 – Pin 6 – A
Pin 7 Cin 2 + Pin 7 – CLK
Pin 8 Cin 2 – Pin 8 + B
Pin 9 reserved Pin 9 – Data
Pin 10 AGND Pin 10 EGND
Pin 11 Vout 1 Pin 11 + Data
Pin 12 Vout 2 Pin 12 +5 Venc
Pin 13 Cout 1 Pin 13 +10 Vref
Pin 14 24 Vsens Pin 14 +24 Venc
Pin 15 reserved Pin 15 reserved
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Black
Pink
Grey/Pink
Red/Blue
White/Green
Brown/Green
Grey
Violet
Yellow
White + Blue
Green
Brown
White/Yellow
Red
Yellow/Brown
1
2