Installation 17/19
RE 30220-B/05.2019, Valve amplifier VT-MRPA1, Bosch Rexroth AG
Tabelle 7: Recommended cable variants
Interface Maximum
length [m]
Cable type Minimum
cross-section [mm
2
]
Enable
30
Unshielded 0.25 to 2.5
50
Ready for operation
30
Unshielded 0.25 to 2.5
50
Command/actual value
30
Twisted wires, shielded 0.25 to 2.5
50
Solenoid cable
20
Shielded
1.0 to 1.5
50 1.5 to 2.5
Operating voltage
20
Unshielded
1.0 to 1.5
50 1.5 to 2.5
Position transducer
30
Twisted wires, shielded 0.5 to 2.5
50
Tabelle 8: Clamping range, rated connection
Min. Max.
Rigid 0.2 mm² 2.5 mm²
Flexible 0.2 mm² 2.5 mm²
Flexible with wire end ferrule 0.25 mm² 2.5 mm²
The length to be stripped is 10 mm each.
7.5.2 Connecting the individual contacts
Abb. 3: “PUSH-IN“ contact
Solid wire
With wire end ferrule
Flexible wire
1.
2.
3.