22/36 Commissioning
Bosch Rexroth AG, Valve amplifier VT-MRPA1, RE 30220-B/05.2019
The ready LED blinks red/green, if the valve size saved last and the current
rotary switch position do not match!
The amplifier is active and utilizes the parameters of the valve size saved last.
Remedy:
If you wish to change the valve size, remove the command value and the enable,
set the new size, press key [Set] > 1 sec and accept the new valve size.
If the rotary switch position was changed accidentally, reset it to the original
valve size.
The ready LED is lit green.
In both cases, check the actually connected valve and its size!
Whenever a valve size is changed, all changeable parameters are reset to factory
settings!