EasyManua.ls Logo

Bosch Rexroth VT-MSPA2-2X/ A5/1A0/000 - Operating and Display Elements

Bosch Rexroth VT-MSPA2-2X/ A5/1A0/000
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20/36 Valve amplifier VT-MSPA2-2X | Commissioning
Bosch Rexroth AG, Edition 04.2020, RE 30232-01-B
8.2 OPERATING AND DISPLAY ELEMENTS
No. Meaning
1 Status LEDs
Indicate the current operational state, menu levels and erroneous states
2 SET key
Editing of the selected parameters, selection of the operating mode, selection of the
“Expert Mode“
3 Keys + / -
Selection of parameters and setting of parameter values
4 Rotary switch
Selection of the valve type
5 Test jacks
8.2.1 Status LEDs
Permanently on
Flashing
Flickering
Off
DI Digital (enable) input
t Ramp
Z/B Command value zero point / biasing current
G Command value attenuator
S Command value step height
Ready for operation
1st quadrant (positive command value, increasing)
2nd quadrant (positive command value, falling)
3rd quadrant (negative command value, increasing)
4th quadrant (negative command value, falling)
Table 10: Indicator lamps
4
8
5
1
6
2
7
3
12
9
10 11
Set
t
DI
Z/B
G
S
I
B
I
A
v
T
Valve
Select
0
9
8
7
6
5
4
3
2
1
MSPA2
1
2
3
4
5
Blinking code
Description of LED
indicator lamps
Indicator lamps Operational state Display mode Meaning
LED DI “digital
input“ (yellow)
Normal operation Permanently ON/OFF Status of digital input
Setup Flashing Standard setup active
Setup Off Expert setup active
Setup ON/blinking/flickering Expert setup: Setting of enable input
LED “ready“
(red/green)
Normal operation Permanently on green Module ready for operation
Normal operation Permanently on red Error
Normal operation and setup Blinking red/green Valve number changed (but not confirmed)
Normal operation and setup Blinking red Invalid valve number
Normal operation Off Module not ready for operation
Setup Flashing green Expert setup active