Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
+44 (0)1204 699959
enquiries@hyquip.co.uk
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
www.hyquip.co.uk/web/index
28/48 Bosch Rexroth AG | Hydraulics Installation and operation | RE 30523-B/09.13
4 Operating the VSPD
Fig. 11 Menu tree „Command Adjust. Part 1“
Level 1 Level 2 Level 3 Level 4 Level 5
Command
Adjust.
Press “ENTER + ESC“
Overlap
to go to the configura-
tion menu
Deadband
[0.0~+100.0] %
Step +
[0.0~+100.0] %
Step -
[0.0~+100.0] %
Offset
[-100.00~+100.00] %
Limit
Limit +
[0.0~+100.0] %
Limit -
[0.0~+100.0] %
Current Curve User 1
Precurrent
[0~+3000] mA
Jump Current
[0~+3000] mA
Max. Current
[0~+3000] mA
Current Curve User 2
X0
[-100.0~+100.0] %
Y0
[0~+3000] mA
X1 …
Y1 …
X2 …
Y2 …
X3 …
Y3 …
X4 …
Y4
…
X5
…
Y5 …
X6 …
Y6 …
X7 …
Y7 …