80
VIII.
VIII.
Troubleshooting
Troubleshooting
Circulation Pump
Circulation Pump
–
–
Pump & Motor Part # Changes
Pump & Motor Part # Changes
HINT: The preferred repair for
replacing pump impellers is the #
167085 impeller kit. The other
solution is using complete pump
assembly # 239144. The # 266511
pump motor only should only be used if
the motor fails (which rarely happens).
NOTE
: The # 167085 impeller kit
and # 263835 index UC/06
circulation pump motor only part #’s
have not changed and still are used.
NOTE
: The circulation pump
assembly part # has been changed
from # 266511 to # 239144.
Please check all pumps ordered or
already in stock to make sure they
show part # 239144.
# 167085
impeller kit
# 167235
capacitor
# 266511
motor only
# 239144
complete pump
assembly
# 266514 front pump housing
# 267739
rear pump
housing
# 171598 sump-pump gasket
The softer bearing (UC/07, UC/11 & UC/12 index) circulation pump and motor
only part #’s for all B & G models have been changed to make
parts ordering more consistent throughout the world. All B & G
parts in stock have been changed to these new part #’s as follows:
• 239144 -- complete circulation
pump assembly (with impeller) for
all B & G
dishwasher models with softer
bearing (all models with index #’s
UC/07, UC/11 & UC/12)
• 266511 -- circulation pump motor
only for all B & G
dishwasher models with softer
bearing (all models with index #’s
UC/07, UC/11 & UC/12)