Bosch Security Systems 09/07 BLCC500R FTR1.02


Copyright © 2007 E&OE
Comms > Telephone Number >
Call Forward Off
MENU 5-1-7
1 Digits 32
# 6 1 #
Use [] and [] Keys To Scroll Cursor. Enter [0] – [9] For Telephone
Digits. Use [] and [] To Toggle Special Characters # and , (Pause)
Comms > Properties >
Call Attempt Count
MENU 5-2-0
0 6
Enter 0 - 15 Then Press [OK] To Program The Maximum Call Retry
Attempts Per Destination
Comms > Properties >
Dialer Options MENU 5-2-1
1 Dialler Enabled Y
2 Pulse Dialling N
3 Dial Tone Detect Y
4 Busy Tone Detect N
5 Mirror Reports To Web Y
6 Extend Handshake Wait Period To 1 Minute N
7 Reserved N
8 Abort Failed Reports Y
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
i

DTMF dialling should be use at all times.
Pulse or decadic dialling should not be selected.
Comms > Properties >
Phone Line Options
MENU 5-2-2
1 Display Telephone Line Fail Y
2 Report Telephone Line Fail Y
3 Alarm On Line Fail If Armed Y
4 Alarm On Line Fail If Disarmed N
5 Reserved N
6 Reserved N
7 Reserved N
8 Display Phone In Use N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Comms > Properties >
Country
MENU 5-2-3
1 = Australia
1
2 = New Zealand 7 = Portugal 12 = China
3 = Italy 8 = Hungary 13 = Hong Kong
4 = Greece 9 = Czech Republic 14 = Malaysia
5 = Cyprus 10 = Poland 15 = Brazil
6 = Spain 11 = Bulgaria
Enter 1 – 15 + [OK] To Set Which Country The Panel Is Being Used In.
Only 1 Location Can Be Programmed. (*** System Wide Parameter ***)
Comms > Properties >
Set SMS Pasword
MENU 5-2-7
p a s s w d
Use keys 0 - 9 To Program SMS Password + [OK] To Save. Use [] and
[] Keys To Scroll Cursor. Default password is for Telstra in Australia.
Comms > Remote Access >
Call Back Number
MENU 5-3-0
1 Digits 32
Use [] and [] Keys To Scroll Cursor. Enter [0] – [9] For Telephone
Digits. Use [] and [] To Toggle Special Characters # and , (Pause)
Comms > Remote Access >
RAS Security PIN
MENU 5-3-1
1 2 3 4 5 6 7 8
Use keys 0 - 9 To Program RAS Security PIN + [OK] To Save. This
security PIN is used the authenticate during remote access connections.
You should not leave this PIN at the default value.
Comms > Remote Access >
Log Threshold
MENU 5-3-2
7 0 %
Enter 0 - 9 To Program Log Threshold + [OK] To Save
Comms > Remote Access >
Ring Count
MENU 5-3-3
0 = No Answer 10
1 to 15 = Answer Ring Count
Enter 0 - 15 Then Press [OK] To Program The Ring Count -
Single Option Only
Comms > Remote Access >
Solution Link RAS Options MENU 5-3-4
1 RAS Allowed Y
2 Call Back Verification Required N
3 Terminate RAS on Alarm Y
4 Answer Machine Bypass Y
5 Answer Incoming Call Only If Armed N
6 Tone Bypass Y
7 Allow User Functions Via Remote Access Software Y
8 Report / Log RAS Start / End Sessions Y
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.

Other manuals for Bosch Solution 16i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16i and is the answer not in the manual?

Bosch Solution 16i Specifications

General IconGeneral
BrandBosch
ModelSolution 16i
CategorySecurity System
LanguageEnglish

Related product manuals