CC408 | Quick Reference Guide | 2. Installer’s Programming Commands EN | 8
Bosch Security Systems | 6/04 | 4998152468B
2.9 Add/Delete User Code/RF
Keyfob
2.9.1 Add a User Code
1. Enter the Master Code followed by the [1] and
[#] keys (for example, [2 5 8 0 1 #]).
2. Enter the user number (1 to 16) to
add/change, followed by the [#] key.
3. Enter the new code followed by the [#] key.
2.9.2 Add an RF Keyfob
1. Enter the Master Code followed by the [1] and
[#] keys (for example, [2 5 8 0 1 #]).
2. Enter the user number (9 to 16) to add,
followed by the [#] key.
3. Enter the nine-digit RF keyfob ID number,
followed by the [#] key.
You can only program User Codes 9 to 16
as RF users.
2.9.3 Delete a User Code/RF Keyfob
1. Enter the Master Code followed by the [1] and
[#] keys (for example, [2 5 8 0 1 #]).
2. Enter the user number (1 to 16) to delete,
followed by the [#] key.
3. Press the [*] key to delete the user code.
2.10 Change Domestic Telephone
Numbers
1. Enter the Installer Code or Master Code
followed by the [2] and [#] keys (for example,
[1 2 3 4 2 #]).
2. Enter the digits for the telephone number.
3. If changing more than one telephone number,
enter [* 4] (which inserts a break between
phone numbers), then repeat Step 2.
4. Press the [#] key to exit.
2.11 Turn Outputs On/Off
1. Enter the Master Code followed by the [5] and
[#] keys (for example, [2 5 8 0 5 #]).
2. Enter the output number (1 to 3) to toggle on
or off.
3. Press the [#] key to toggle the output on, or
the [*] key to toggle the output off.
4. Press the [#] key to exit.
2.12 Setting Date and Time
1. Enter the Master Code followed by the [6] and
[#] keys (for example, [2 5 8 0 6 #]).
2. Enter the day (DD), month (MM), and year
(YY), followed by the hour (HH) and minute
(MM).
3. Press the [#] key to exit.
2.13 Day Alarm – Toggle On/Off
Press and hold the [4] key until two beeps sound.
Day alarm toggles on or off.
2.14 STAY Mode 2 Zones - Program
1. Enter the Installer Code or Master Code
followed by the [4] and [#] keys (for example,
[1 2 3 4 4 #]).
2. Enter the zone number the system should
automatically isolate, followed by the [*] key.
3. Repeat Step 2 if more than one zone should
be automatically isolated when armed in
STAY Mode 2.
4. Press the [#] key to exit.
2.15 Fault Analysis
1. Press and hold the [5] key until two beeps
sound.
2. Zone indicators display FAULT condition.
Refer to Table 6.
3. Press the [#] key to exit.
Table 6: Fault Condition Indicators
Zone LED FAULT Condition
1 Battery low
2 Date/time reset
3 Sensor watch fail
4 Horn speaker fail
5 Telephone line fail
6 EPROM fault
7 Fuse fail
8 Communication fail
2.16 Modem Call (Alarm Link)
Press and hold the [6] key until two beeps sound.
2.17 Latching Outputs (Reset)
Press and hold the [7] key until two beeps sound.
2.18 Codepad ID/Buzzer Tone
1. Press and hold the [8] key until you reach the
desired buzzer tone.
If the system is partitioned, the keypad first
displays the area to which the keypad is
assigned.
Table 7: Codepad ID Assignments
Zone LED Codepad Assignment
1 Area 1
2 Area 2
7 Master partitioned codepad
2. Press the [#] key to exit.
2.19 Test Report
Press and hold the [9] key until two beeps sound.
2.20 Speaker Test
Press and hold the [1] key until two beeps sound.
The speaker sounds for 2 seconds.