Installation and Maintenance Manual
TA Series
6 720 220 046
Revised 03-11

Questions and Answers

  • D
    David SmithJul 29, 2025
    What to do if my Bosch Heat Pump has no flow or low flow?
    • J
      Justin CharlesJul 29, 2025
      If your Bosch Heat Pump experiences no flow or low flow, several factors could be the cause. Here's what you can check: * Ensure the power supply is working. * Verify the on/off switch is in the 'ON' position. * Engage the heat pump contactor. * Inspect for and repair any broken or loose wires. * Purge any air from the piping system. * Remove the pump cartridge and clean it if the pump shaft/impeller is stuck. * Consider replacing the pump if it's defective. * Repair any kinks in the water piping and check for proper line size.

Summary

Initial Inspection

General Description

Moving and Storage

Safety Considerations

Location

Installation

Mounting Vertical Units

Instructions for mounting vertical units, including pad requirements.

Mounting Horizontal Units

Condensate Drain

Duct System

Piping

Specifications and recommendations for water piping connections.

Electrical

Requirements for field wiring and compliance with electrical codes.

ECM Interface Board

ECM Interface Board Thermostat Connections

Description of thermostat wiring and terminal functions on the ECM board.

Motor Profile Air Flow Table

Safety Devices and the UPM Controller

Considerations for Electric Heater Package

Electric Heater Package Option

Well Water Systems

Sequence of Operation - Two Stage Units

Cooling Mode

Step-by-step operation during the cooling cycle.

Heating Mode

Step-by-step operation during the heating cycle.

Installation of Pressure Regulating Valves

Cooling Tower;Boiler Systems

Earth Coupled Systems

System Checkout

Unit Start-Up

Heat Recovery Package

Typical Connection Piping

Water Tank Preparation

Steps for preparing a water tank for heat recovery connection.

HR Water Piping

Specifications for hot water piping for the heat recovery system.

Water Tank Refill

Initial Start-Up

Maintenance

Troubleshooting

Well Water Application

Cooling Tower;Boiler Application

Earth Coupled Application

Typical Wiring Diagram: Single Phase ECM Blower Motor

Typical Wiring Diagram: Single Phase ECM Blower Motor-Electric Heat

Operating Pressures & Temperatures

Operating Pressures & Temperatures (Continued)

Operating Pressures & Temperatures (Continued)

Operating Pressures & Temperatures (Continued)

Unit Check-Out Sheet

Troubleshooting

Troubleshooting (Continued)

Bosch TA025 Specifications

General IconGeneral
BrandBosch
ModelTA025
CategoryHeat Pump
LanguageEnglish