Installation, Operation, and Maintenance Manual
Greensource CDi Series TW Model Water-to-Water Heat Pumps
Greensource
8733954853 (2020/04)
TW025 | TW035 | TW049 | TW061 | TW122

Questions and Answers

  • R
    Rebecca CarlsonAug 8, 2025
    How to troubleshoot a Bosch Greensource TW049 Heat Pump that does not run?
    • K
      Karen MunozAug 8, 2025
      If your Bosch Heat Pump isn't running, first ensure the power supply is on by closing the disconnect. If that doesn't work, check for a blown fuse or tripped breaker and replace or reset it, making sure fuses are the correct size. Finally, verify the voltage supply; if it's below the minimum specified on the unit's data plate, contact your local power company.
  • A
    amy11Aug 17, 2025
    What to do if my Bosch Heat Pump turns off due to high-pressure control?
    • R
      Raymond HintonAug 17, 2025
      If your Bosch Heat Pump shuts off due to high pressure, the discharge pressure might be too high. If in cooling mode, check for lack of water flow, excessively warm entering water temperature, or a scaled/plugged condenser. If in heating mode, check for inadequate load side fluid flow. Also, the unit might be overcharged with refrigerant, in which case you should reclaim refrigerant, evacuate, and recharge to the factory-recommended level. Check the high-pressure switch for defects or improper calibration. Furthermore, if your unit uses a UMC and a 40°F freeze sensor, this sensor being in series with the HP switch can register as a high-pressure fault.
  • M
    Marcus ClementsAug 23, 2025
    What causes a Bosch Greensource TW049 Heat Pump to turn off due to low-pressure control?
    • W
      wriveraAug 23, 2025
      If your Bosch Heat Pump shuts off due to low pressure, the suction pressure might be too low. If in cooling mode, check for inadequate source-side fluid flow or excessively cold entering water temperature. If in heating mode, check for inadequate water flow, excessively cold entering water temperature, or a scaled/plugged condenser. Also, the unit might be low on refrigerant; check for leaks, repair them, evacuate, and recharge to the factory-recommended level. Inspect the low-pressure switch for defects or improper calibration. If your unit uses a UMC and the DPS option, this sensor being in series with the LP switch can register as a low-pressure fault.
  • D
    Donald JarvisAug 28, 2025
    How to fix no flow or low flow in my Bosch Heat Pump?
    • M
      Megan Leonard DDSAug 28, 2025
      If your Bosch Heat Pump has no or low flow, check the power supply and ensure the on/off switch is in the 'ON' position. Engage the heat pump contactor and inspect for broken or loose wires, repairing or tightening them as needed. Purge any air from the piping system. Remove the pump cartridge and clean it if the pump shaft/impeller is stuck. If the pump is defective, replace it. Finally, repair any kinks in the water piping and ensure it's the proper size.
  • J
    Joshua MarquezSep 1, 2025
    Why does my Bosch Heat Pump keep short cycling?
    • J
      jacksonoliviaSep 1, 2025
      If your Bosch Heat Pump is short cycling, first recalculate the heating and cooling loads to ensure the unit isn't oversized. If the thermostat is near a supply air grill, relocate it and adjust the heat anticipator. Check the wiring and controls, looking for a defective or improperly calibrated low-pressure switch.
  • M
    Michael BakerNov 11, 2025
    Why is my Bosch Heat Pump not cooling or heating sufficiently?
    • M
      Michelle JacksonNov 11, 2025
      If your Bosch Heat Pump isn't providing enough cooling or heating, start by checking for adequate fluid flow. Also, examine the refrigerant charge, as a low charge can cause inefficient operation. Inspect the compressor for defects—if the discharge is too low and suction pressure is too high, the compressor may not be pumping correctly and may need replacement. Also, the refrigerant system may be contaminated with moisture or non-condensables. Reclaim refrigerant, replace filter dryer, evacuate the refrigerant system, and recharge with factory recommended charge. Other potential issues include a defective reversing valve (creating a bypass), TXV issues (restrictions or defects), and incorrect operating pressures (compare to the unit's pressure/temperature chart). Finally, recalculate heati...

Summary

Safety Warnings

General Safety Precautions

Outlines essential safety measures for installation and servicing.

Chemical Exposure Warning

Warns about potential chemical exposure, including Lead.

Unit Installation Procedures

Location, Mounting, and Piping

Guidelines for unit placement, vibration isolation, and fluid connections.

Electrical and System Integration

Covers electrical wiring, safety devices, application considerations, and checks.

Specific Application Considerations

Well Water Systems

Details copper vs. cupro-nickel heat exchangers for well water.

Cooling Tower;Boiler Systems

Geothermal Systems

Post-Installation System Checkout

System Operation Guide

Unit Start-Up Sequence

Step-by-step guide for initiating unit operation.

Heating and Cooling Operation

Explains operational logic for cooling and heating modes.

Heat Recovery Package (HRP) Setup

Water Tank Preparation

Steps for preparing the domestic water tank for HRP connection.

Water Tank Refill

Instructions for refilling the water tank after HRP installation.

Initial HRP System Start-Up

Procedures for the initial startup of the HRP system.

Safety Devices and UPM Controller

UPM Controller Overview

Introduces the Unit Protection Module and its function.

Safety Control Functions

Details high-pressure, low-pressure, and freeze protection mechanisms.

Safety Devices and UPM II Controller

Water-To-Water Unit Controller

Operating Instructions

Low-Temperature Loop Application

Controller Initial Configuration

Troubleshooting

Unit Troubleshooting Guide

Lists common unit problems, causes, and corrections.

Decommissioning and Environmental Care

Wiring Diagrams

Bosch Greensource TW049 Specifications