Installation, Operation, and Maintenance Manual
Greensource CDi Series TW Model Water-to-Water Heat Pumps
Greensource
8733954853 (2020/04)
TW025 | TW035 | TW049 | TW061 | TW122

Questions and Answers

  • R
    Rebecca SuarezAug 7, 2025
    How to troubleshoot a Bosch Greensource TW061 Heat Pump that does not run?
    • M
      maria73Aug 7, 2025
      If your Bosch Heat Pump isn't running, first ensure the power supply is on by closing the disconnect. If that doesn't work, check for a blown fuse or tripped breaker and replace or reset it, making sure fuses are the correct size. Finally, verify the voltage supply; if it's below the minimum specified on the unit's data plate, contact your local power company.
  • R
    Robert BoydAug 17, 2025
    What to do if my Bosch Greensource TW061 turns off due to high-pressure control?
    • B
      burnstravisAug 17, 2025
      If your Bosch Heat Pump shuts off due to high pressure, the discharge pressure might be too high. If in cooling mode, check for lack of water flow, excessively warm entering water temperature, or a scaled/plugged condenser. If in heating mode, check for inadequate load side fluid flow. Also, the unit might be overcharged with refrigerant, in which case you should reclaim refrigerant, evacuate, and recharge to the factory-recommended level. Check the high-pressure switch for defects or improper calibration. Furthermore, if your unit uses a UMC and a 40°F freeze sensor, this sensor being in series with the HP switch can register as a high-pressure fault.
  • Z
    zdavisAug 22, 2025
    What causes a Bosch Heat Pump to turn off due to low-pressure control?
    • Q
      qsanchezAug 22, 2025
      If your Bosch Heat Pump shuts off due to low pressure, the suction pressure might be too low. If in cooling mode, check for inadequate source-side fluid flow or excessively cold entering water temperature. If in heating mode, check for inadequate water flow, excessively cold entering water temperature, or a scaled/plugged condenser. Also, the unit might be low on refrigerant; check for leaks, repair them, evacuate, and recharge to the factory-recommended level. Inspect the low-pressure switch for defects or improper calibration. If your unit uses a UMC and the DPS option, this sensor being in series with the LP switch can register as a low-pressure fault.
  • I
    Isabella RaymondAug 27, 2025
    How to fix no flow or low flow in my Bosch Heat Pump?
    • E
      Eric HudsonAug 27, 2025
      If your Bosch Heat Pump has no or low flow, check the power supply and ensure the on/off switch is in the 'ON' position. Engage the heat pump contactor and inspect for broken or loose wires, repairing or tightening them as needed. Purge any air from the piping system. Remove the pump cartridge and clean it if the pump shaft/impeller is stuck. If the pump is defective, replace it. Finally, repair any kinks in the water piping and ensure it's the proper size.
  • E
    Emily HendricksSep 2, 2025
    Why does my Bosch Heat Pump keep short cycling?
    • M
      Michael OconnorSep 2, 2025
      If your Bosch Heat Pump is short cycling, first recalculate the heating and cooling loads to ensure the unit isn't oversized. If the thermostat is near a supply air grill, relocate it and adjust the heat anticipator. Check the wiring and controls, looking for a defective or improperly calibrated low-pressure switch.
  • M
    Melanie MarshNov 11, 2025
    Why is my Bosch Heat Pump not cooling or heating sufficiently?
    • S
      smithanthonyNov 11, 2025
      If your Bosch Heat Pump isn't providing enough cooling or heating, start by checking for adequate fluid flow. Also, examine the refrigerant charge, as a low charge can cause inefficient operation. Inspect the compressor for defects—if the discharge is too low and suction pressure is too high, the compressor may not be pumping correctly and may need replacement. Also, the refrigerant system may be contaminated with moisture or non-condensables. Reclaim refrigerant, replace filter dryer, evacuate the refrigerant system, and recharge with factory recommended charge. Other potential issues include a defective reversing valve (creating a bypass), TXV issues (restrictions or defects), and incorrect operating pressures (compare to the unit's pressure/temperature chart). Finally, recalculate heati...

Summary

Safety Warnings

Model Nomenclature

Standard TW Package

Unit Installation

Safety and Control Systems

Details safety devices and the Unit Protection Module (UPM).

Post-Installation Checks

Lists essential checks after installation before unit energization.

Specific Application Considerations

Post-Installation System Checkout

System Operation

Unit Start-Up

Step-by-step guide for initiating the heat pump's operation in cooling and heating modes.

Options

Heat Recovery Package (HRP)

Details the factory-installed HRP for domestic hot water heating using waste heat.

Heat Recovery Package (HRP) Setup

Safety Devices and the UPM Controller

Safety Devices and the UPM II Controller

Water-To-Water Unit Controller

Operational Modes and Protection

Details heating, cooling, auto-changeover modes, and unit protection mechanisms.

User Interface and Operation

Guides on using the interface, setting up, and managing operations like lockout and pump cycling.

Initial Configuration

Steps to configure the controller's settings after power-up.

Configuration Fields

Explains various display fields for configuring temperature scale, pump mode, and compressor settings.

Low-Temperature Loop Application

Water Quality Table

Troubleshooting

Unit Troubleshooting

Lists problems, possible causes, and checks/corrections for unit malfunctions.

HRP Troubleshooting

Lists problems, causes, and checks for Heat Recovery Package (HRP) issues.

Unit Lockouts

Explains common causes of unit shutdowns and lockout conditions.

Maintenance

Wiring Diagrams