Bosch tca60f9 - Replacing the Thermal Fuse

Bosch tca60f9
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58300000111195_ARA_en_f.doc – 02.06.09 Seite 65 von 102
6.3 Replacing the thermal fuse
The thermal fuse (STB) is a safety element which is
used to prevent damage caused by the heate
r
overheating. To ensure correct function, it is essential to
install the thermal fuse properly.
Whenever the appliance is repaired, check as
a precaution that the thermal fuse is in perfect
condition and is correctly installed!
6.3.1 Checking an installed thermal fuse:
The following points must be checked:
Position and attachment of the Teflon hose (must be firmly
anchored)
Position of the thermal fuse (centred under installation
bracket)
Quality of the cable connections
Bend correct
Installation bracket is firmly attached
6.3.2 Component
The thermal fuse is supplied as a pre-assembled component.
(Wire colour and type may deviate in reality).
6.3.3 Installation location
1 Screw with circlip
2 Installation bracket
3 Heater