58300000111195_ARA_en_f.doc – 02.06.09 Seite 65 von 102
6.3 Replacing the thermal fuse
The thermal fuse (STB) is a safety element which is
used to prevent damage caused by the heate
overheating. To ensure correct function, it is essential to
install the thermal fuse properly.
► Whenever the appliance is repaired, check as
a precaution that the thermal fuse is in perfect
condition and is correctly installed!
6.3.1 Checking an installed thermal fuse:
The following points must be checked:
► Position and attachment of the Teflon hose (must be firmly
anchored)
► Position of the thermal fuse (centred under installation
bracket)
► Quality of the cable connections
► Bend correct
► Installation bracket is firmly attached
6.3.2 Component
The thermal fuse is supplied as a pre-assembled component.
(Wire colour and type may deviate in reality).
6.3.3 Installation location
1 Screw with circlip
2 Installation bracket
3 Heater