7 FAULT DIAGNOSTICS
7.1 Malfunctions
7.1.1 Drawing coffee
Complaint Cause? Remedial action
Coffee temperature too low
Cold cup or cold milk in the cup Prewarm cup or rinse out with hot water.
Heat milk.
(Measure coffee temperature
5–10 mm under coffee outlet!)
Brewing system not prewarmed (1st coffee
brewing process after appliance switched on),
low amount of liquid (e.g. espresso)
Prewarm brewing system; to do this open
and close ground coffee duct flap and start a
coffee brewing process.
Rotate function selector briefly to draw
steam in order to increase the temperature.
Appliance calcified Descale.
Heater has heated up to steam temperature
Coffee temperature too high
NTC temperature sensor defective
NTC temperature sensor not screwed on
correctly
Cool down heater by drawing hot water
Replace NTC temperature sensor
Tighten NTC temperature sensor
Logic module defective Replace logic module
Coffee has too little aroma
Grinding unit setting not optimum Adjust grinding unit setting. (Change degree
of grinding only while the grinding unit is
running)
Unsuitable coffee or beans no longer fresh Change coffee or use fresh beans.