7.1.2 Drawing coffee
Complaint Cause? Remedial action
Coffee has no “crema”
Unsuitable coffee or beans no longer fresh Change coffee or use fresh beans
Grinding unit setting not adjusted optimally to
coffee beans
(Layer of froth)
Brewing system dirty
Adjust grinding unit setting. (Change degree
of grinding only while the grinding unit is
running)
Run descaling and cleaning programmes
Coffee levels differ
– when simultaneously filling
two cups (> +/– 15%)
Appliance not level
Outlet distributor dirty or defective
Place appliance on a level base
Replace outlet distributor
Hose system or drainage valve leaking
During a brewing process check hose system
and drainage valve for leaks
– when drawing several cups
in succession
Drainage valve leaking due to coffee dregs Run descaling programme
Replace drainage valve
Incorrect pulsing from flowmeter Check hose system between flowmeter and
pump. If hose length = 6 cm replace hose
with kit mat. no. 49 3828 (hose = 22 cm)
Coffee is only dripping out
Degree of grinding setting too fine Set a coarser degree of grinding.
– tastes too bitter Coffee ground too finely
Use coarser ground coffee or reduce dosage.
Brewing filter blocked or silted up Clean brewing filter or run cleaning pro-
gramme.