58300000111195_ARA_en_f.doc – 02.06.09 Seite 93 von 102
Appliance does not switch on
5. Check voltage at power module output to transformer (220–240
VAC)
Check voltage on plug CP2B on power module.
No voltage defective power module (if voltage between F1
and F2 = 220–240 VAC)
Power supply available see Point 6
6. Check voltage at power module input from transformer
The secondary voltages (15 VDC / 9 VDC) of the transformer are
measured on the flat plug CP4 (2 x red = 15 VDC / 2 x white = 9 VDC)
No voltage defective transformer
No 15 VDC voltage defective transformer
No 9 VDC voltage defective transformer
Voltage available see Point 7
7. Check voltage at power module output to logic (5 VDC)
The output voltage is measured from the power module to the logic
module (control electronics) on plug CP9, terminals 1 = GND (brown)
and 2 = + 5V (red).
No voltage defective power module
Voltage available see Point 8
8. Check voltage on logic module input
Measure voltage input on plug CM9 of the logic module on terminals 1
= GND (brown) and 2 = + 5 V (red).
No voltage
defective ribbon cable
Voltage available
defective logic module