7.5.4 Pump is not functioning
Fault description:
Pump is not actuated / is not pumping
Possible faults:
1. No control signal voltage from logic module
2. No voltage at power module pump output
3. No voltage at thermostat input
4. No voltage on the pump
Troubleshooting:
1. Check control signal voltage from logic module
To do this, open the appliance. Using the Torx T10 screwdriver,
unscrew all rear panel screws and remove the rear panel. Remove
upper appliance cover to the rear. Remove both side panels upwards.
The control signal voltage is measured on plug CM9 on terminals 1 =
GND (brown) and 8 = 5 VDC (grey). The pump must be actuated by a
coffee brewing process.
No signal voltage Logic module or connecting cable
defective
Voltage available see Point 2
2. Check voltage on power module pump output
The voltage for the pump is measured on plug CP5 on terminal 1 =
phase and the neutral conductor, terminal 4. The pump must be
actuated by a coffee brewing process.
No voltage defective power module
Voltage available see Point 3
3. Check voltage on thermostat input
Before the voltage can be checked on the pump itself, the thermostat
must be tested for function. The pump must not be overheated! The
voltage is measured at the thermostat input – on the right (grey cable
from power module) and at the thermostat output – on the left (grey
cable at pump connection. In both cases the phase connection (black)
of the pump is used as the anti-pole. The pump must be actuated by
a coffee brewing process.
No voltage at the thermostat input defective wiring
No voltage at the thermostat output defective thermostat
Voltage available at thermostat output see Point 4
4. Check voltage on the pump
The pump operating voltage is checked at the terminals of the pump.
No voltage defective thermostat
Voltage available defective pump