EasyManua.ls Logo

Bosch Worcester Danesmoor Utility Regular ErP+ 12/18 - Page 33

Bosch Worcester Danesmoor Utility Regular ErP+ 12/18
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Greenstar Danesmoor Utility
ErP+
and Utility System
ErP+
- 6 720 821 720 (2018/04) 33
Utility - 230V Standard wiring diagram
Fig. 57 230V Standard wiring diagram
1 2 3
A
B
D
Green/Yellow
Green/Yellow
Green/Yellow
Brown
Re
3
2
Grey
Grey
Brown
Brown
= EARTH
= LIVE
= NEUTRAL
Blue
F
6720809436-21.2Wo
Key to components:
A - EARTH STUD
B - HIGH LIMIT THERMOSTAT
C - AIR PRESSURE SWITCH
D - BOILER MANUAL RESET OVERHEAT
THERMOSTAT
E - FLUE MANUAL RESET OVERHEAT
THERMOSTAT
F - TERMINAL CONNECTOR BLOCK
G - CONTROL THERMOSTAT
H - BURNER SOCKET
L3 N L2L1
C
E
H
G