10.11 Removing the heat exchanger
Remove the fan, gas hose and mixing device ( Chapter , page 53).
1. Remove the clip.
2. Detach the flow pipe.
3. Disconnect the cable from the flow temperature sensor on the heat
exchanger.
4. Disconnect the cable from the flue gas temperature limiter.
5. Remove the nut.
Fig. 88 Detach the flow pipe and disconnect the cable
1. Unclip the flue pipe.
2. Push the flue pipe up.
3. Remove the heat exchanger.
Fig. 89 Removing the heat exchanger
10.12 Replacing the control unit
The devices are delivered without code plug.
When replacing the control unit, ensure the code plug supplied is
used.
Flip the electronics panel down (Fig. 46 page 35).
Replace the control unit.
Fig. 90 Replacing the control unit
Open the cover on the enclosure of the appliance electronics.
Insert the code plug.
Fig. 91 Inserting the code plug
1.
2.
3.
4.
5.
0010015950-002
1.
3.
2.
0010015951-002
3.
1.
1.
2.
0010017283-002
1.
2.
0010017275-001

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Worcester GC2000iW 25 C NG and is the answer not in the manual?

Bosch Worcester GC2000iW 25 C NG Specifications

General IconGeneral
BrandBosch
ModelWorcester GC2000iW 25 C NG
CategoryBoiler
LanguageEnglish

Related product manuals