6 720 612 217 (05.03)
1.4 Description of function
For a simplified diagram of the system,
refer to Figure 2 on page 16.
Temperature differential regulator
The temperature differential regulator
controls the operation of the solar heat-
ing system pump.
The solar heating system pump is
switched on when the difference
between the solar panel tempera-
ture and the storage tank temper-
ature exceeds the ON threshold
of
8 K (°C).
The display shows the sun symbol
and the symbol moves (Fig. 3).
The solar heating system pump is
switched off when the difference
between the solar panel tempera-
ture and the storage tank temper-
ature falls below the OFF
threshold of 4 K.
The sun symbol disappears from the
display and the symbol stops
moving (Fig. 3).
ON threshold for solar heating sys-
tem pump:
- temperature difference of 8 K
OFF threshold for solar heating sys-
tem pump:
- temperature difference of 4 K.
Storage tank temperature limiter
The storage tank temperature limiter
prevents the domestic hot water
becoming too hot:
Normal setting = 60°C.
Function:
The solar heating system pump is
switched off if the storage tank tem-
perature sensor reading exceeds
the set temperature. The symbol
stops moving and max flashes
(Fig. 4, page 16).
The solar heating system pump is
switched on again as soon as the
storage tank temperature drops
below the set temperature limit by
4 K. The symbol moves and max
disappears from the display (Fig. 4,
page 16).
Warning: Risk of
scalding from storage
tank temperatures
over 60 °C!