Commissioning
6 720 612 217 (05.03)
Cable exits to rear:
Break open with a suitable tool
through the programmer casing
backplate (Fig. 6).
Cable exit to underneath:
B Secure cable with cable grip.
Cable exit to rear:
B Provide means of securing cable
outside programmer casing.
B Use a screwdriver to lock the snap-
fit terminals (Fig. 9).
B Make all electrical connections (see
Fig. 10).
4 Commissioning
B Switch on power supply.
B Set mode selector switch S to auto-
matic mode.
AUT briefly appears on the display
and the controller is set to automatic
mode.
i
On fine wire leads:
B Use cable-end
sleeves.
i
Maximum lead cross-sec-
tion 2.5 mm
2
for each
snap-fit terminal.
i
The sensors and
have to be connected be-
fore the TDS 10 will func-
tion.
i
Check that the solar
heating system has
been filled and vented
according to the in-
structions for the solar
panel and the solar
pump station.