Adjustments (must be carried out only by qualied technicians) | 15
Minimum gas ow adjustment
6.3 Conversion to a dierent type of gas
Only use the original conversion kits.
The conversion must only be performed by a qualied
technician. The original conversion kits are supplied with
assembly instructions.
The minimum gas ow adjustment is performed
automatically after the adjustment of the
maximum gas ow.
Natural gas H Butane Propane
Injector code
WR11
8708202113
(1,10)
8708202130
(0,70)
8708202124
(1,20)
8708202128
(0,72)
WR14
8708202113
(1,10)
8708202128
(0,72)
8708202116
(1,25)
8708202132
(0,75)
WR18
8708202115
(1,15)
8708202130
(0,70)
8708202116
(1,25)
8708202132
(0,75)
Connection
pressure
(psi)
WR11
WR14
WR18
32 3
MAX (psi)
WR11
8,272,1 3,5
WR14
8,22,1 3,5
WR18
55,230,1 3,25
Table 8 Burner pressure