2 Technical Characteristics and Dimensions
2.1 Declaration of conformity with relevant EEC
regulations
This appliance fullls European directive requirements 2009/
142/EC, 2006/95/EC, 2004/108/EC and corresponds to the
specications described in the corresponding EEC certicate
of proof.
2.2 Explanation of Model Code
[W] Gas Water Heater
[R] Proportional power adjustment
[11] Capacity (l/min)
[B] Electronic ignition powered by 1.5 V batteries
[23] Indicator number of natural gas H
[31] Indicator number of LPG
[S...] Country code
The code number indicates the gas group according to EN 437:
2.3 Accessories (Included with Appliance)
Gas water heater,
Attachment elements,
Installation accessories,
Two 1.5 V batteries type R
Heater docu
mentation.
2.4 Description of the heater
Operating convenience, as the heater is ready to operate by
simply pressing a switch.
Heater for wall-mounting,
Ignition by electronic device triggered when the water valve
opens,
Great savings in comparison with conventional heaters,
due to the possibility of power adjustment and no
permanent pilot ame,
Natural gas/LPG burner,
Semi-permanent pilot burner which only functions during
the period between the opening of the water valve and the
ignition of the main burner,
Heat exchanger in copper without tin/lead covering,
Water valve in breglass-reinforced polyamide, 100%
recyclable,
Automatic adjustment of the water ow by means of a
device which permits a constant ow to be maintained in
spite of
variable pressure supplies,
Gas ow adjustment proportional to the water ow to
maintain a constant high temperature.
Safety devices:
Ionisation probe to check for accidental extinction of
the burner ame,
Flue gas safety device which turns o the heater in case
of inadequate combusted gas evacuation conditions,
Temperature limiter which prevents overheating of the
heat exchanger.
2.5 Type overview
The type plate is located at the bottom left of the appliance.
There you will nd details of appliance output, model number,
approval data and the serial number.
2.6 Special accessories
Conversion kit from natural gas to butane/propane.
Model WR 11/14/18 B...
Category II
2H3+
Type Type B
Table 2
W R 11 B 23
31
S....
W R 14 B 23
31
S....
W R 18 B 23
31
S....
Table 3
Identication
Code
Wobbe Index (Ws)
(15 °C)
Gas type
23 12,7-15,2 kWh/m
3
Natural Gas - Group H
31 20,2-21,3 kWh/m
3
LPG - Group B/P
Table 4

Related product manuals