6720648592 (2014/05)
8 | Technical Characteristics and Dimensions
2.10 Technical characteristics
Technical characteristics Symbol Units WR11 WR14 WR18
Power and ow
nPrewop lufesu lanimoN Btu/h 65570 80595 104165
nimPrewop lufesu muminiM Btu/h 23905 23905 23905
Useful power (adjustment range) Btu/h 23905-
65570
23905 -
80595
23905 -
104165
nQwolf lamreht lanimoN Btu/h 74450 92210 117825
nimQwolf lamreht muminiM Btu/h 27660 27660 27660
Gas data
1)
1) Hi 15 °C - 1013 mbar - dry: Natural gas 34.02 MJ/m
3
(9.5 kWh/m
3
)
LPG: Butane 45.65 MJ/kg (12.7 kWh/kg) - Propane 46.34 MJ/kg (12.9 kWh/kg)
Supply pressure
02GH sag larutaN kPa 2 2 2
03G)enaporP/enatuB( GPL kPa 2,8 2,8 2,8
Consumption
02GH sag larutaN m3/h 2,2 2,77 3,5
03G)enaporP/enatuB( GPL Kg/h 1,75 2,2 2,79
Number of injectors 12 14 18
Water data
Maximum permissible pressure
2)
2) Considering the water dilution eect this value must not be exceeded.
pw
psi 170 170 170
Temperature selector in fully clockwise position
Temperature rise °C 50 50 50
Flow range l/min 2 - 5,5 2,0 - 7 2,0 - 8,8
nimwperusserp gnitarepo muminiM psi 1,5 1,5 3,0
Minimum pressure for maximum water ow psi 3,6 5,0 7,2
Temperature selector in fully anti-clockwise position
Temperature rise °C 25 25 25
Flow range l/min 4 - 11 4 - 14 4 - 17,6
Minimum pressure for maximum water ow psi 8,7 14,5 19
Combustion products
3)
3) For nominal caloric power.
Minimum low pressure mbar 0,015 0,015 0,015
Flow g/s 13 17 22
Temperature °C 160 170 180
Table 6