6720648592 (2014/05)
Maintenance (must be carried out only by qualied technicians) | 17
7.3 Flue gas safety device
Operation and safety precautions
The ue gas safety device checks the eectiveness of ue gas
extraction by the ue. If it is inadequate, the appliance switches
o automatically so that the combustion fumes do not escape
into the room in which the appliance has been installed. The
ue gas safety device resets after a cooling-down period.
If the appliance shuts down while in operation:
Ventilate the room.
Wait about 10 minutes then restart the appliance.
If the problem recurs, call an engineer.
Maintenance
If faults occur on the ue gas safety device, proceed as follows:
Undo ue gas safety device
xing screw.
Loosen temperature limiters connectors.
Undo magnetic unit connector.
Remove thermocouple.
Replace damaged component with new one and ret using
the reverse of the procedure set out in the table above.
Function check
Flue gas safety device function check:
Disconnect ue pipe;
Replace with pipe (about 50 cm long) with sealed end;
Fit pipe vertically;
Start up appliance at rated output and set temperature
control to maximum temperature;
Under those conditions, the appliance should shut down
after two minutes. Remove temporary pipe and reconnect
ue pipe.
DANGER:
The ue gas safety device must not under any
circumstances be switched o, simulated or
replaced by any other component.
DANGER:
The user must never make any modications
to the ue gas safety device.