Electrical connection
17
Condens 5000W – 6720813952 (2019/02)
[4] Other rooms
[5] Living space
[6] Installation location
[7] External
[8] Outdoor temperature sensor
6.2 Connection of the control units
Electrical work must only be carried out by qualified electrical
contractors.
The terminal strip is located behind the cover.
Unscrew the control panel and hang on the frame.
Fig. 26 Mounting the user interface
Turn the locks a quarter turn clockwise then remove the cover.
Fig. 27 Removing the cover
Connect the components to the relevant plug.
Fig. 28 Terminal strips
[1] 24 V AC terminal strip
[2] 230 V AC terminal strip
6.3 Installation of the strain relief
Always pass the cable to be installed through a supplied strain relief
mechanism before attaching it to a mains plug.
Trim the grommet of the strain relief according to the dimension of
the cable.
Always pass the cable to be installed through a supplied strain relief
mechanism.
Fig. 29 Cable entry
Fasten the corresponding plug to the cable.
Plug the plug in at the terminal strip.
Tighten the screw of the strain relief.
Fig. 30 Tightening the screw
0010010007-001
A
B
0010010008-001