EasyManuals Logo

Bose PowerShare PS602P User Manual

Bose PowerShare PS602P
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Front and Rear
Panels
pro.Bose.com
PS602
Rear Panel
Figure
3.
PowerShare
PS602
amplifier
rear
panel
0
0
0
H
4~
0
4~
4'
u
0
1@
" M
!:
H i l Q
MUTE
~
':'~~
_BOSE:"
~"2S
hare
0
1
-
~)
w
u
~
I.
f lAT
&
(an~
~ n
w
1
~
1
~9
:
,
~
'
.:
·-~
·
6
,Q
I@
·-
~
~
[I]
~
:
·
~
·
=
·
~--
·-·
[§j]
.CSI
OO
usn
E:l
~
,_
~~
t
2®)
OHE
Q
2
IT
~I
:
~::
·
:
:
[Q
_,
OOJil'tlf l
2
~
2~
9.RM\ll(l';
0
O.
RMU
lot
Cl.ASSlWI
AJ
N<:;
100.~
-
so.--w.~
0
0 INPUT
1
&
2-
Balanced
3-pin
Euroblock
and
unbalanced
RCA line-level
input
connectors.
For
each
channel, use
either
balanced
or
unbalanced
input
type,
but
not
both
simultaneously.
8
USB -
Connect
the
amplifier
to
a PC using a USB
connection.
This allows
you
to
use
the
PC-based PowerShare
Editor
software
to
configure
the
advanced
features
of
the
amplifier.
The
CON FIG DIP
switch
must
be
set
to
SOFTWARE
to
configure
the
amplifier
using
the
PowerShare
Editor
software.
See
the
Software
Interface
section
for
more
details
.
0
CHANNEL 1
&
2
EQ-
Each
dial
provides
loudspeaker
equalization
presets
per
channel: DS
16,
DS
40,
DS
100,
FS3B,
402,
802,
MA12EX, RMU105,
and
RMU108. Use
the
Flat
setting
for
FS3 Systems,
or
for
loudspeakers
that
are
not
Bose
or
that
do
not
require EO.
When
EO
is
selected,
the
crossover
and
Vpeak
a
nd
Vrms
limiters
for
that
loudspeaker
are
automatically
loaded. Use
the
PowerShare
Editor
software
to
adjust
any
of
these parameters, see
the
Software
Interface
section
for
more
details. In
Hi-Z
output
mode,
a
50
Hz high-pass
filter
(HPF)
is
automatica
l
ly
added
to
the
Hi-Z
selected
outputs.
The
loudspeaker
EO
is
applied
after
the
50
Hz
HPF.
0
CONTROLCENTER-
RJ-45
input
connector
for
Bose® CC-1
ControiCenter
zone
controllers
or
CV41 4-to-1
Converter
only.
Do
not
use
this
input
to
connect
to
a
network.
0
MUTE-
Contact
closure
connection
where
a
short
across
the
mut
e
connector
will
mute
all
outputs.
This
is
the
Normally
Open
(NO)
default
state. The
mute
polarity
can
be
inverted
to
Normally
Closed (NC),
where
an
open
across
the
mute
connector
will
mute
all
outputs,
using
the
PowerShare
Editor
software.
See
the
Software
Interface
section
for
more
details.
0
DIP
Switches -
A
bank
of
switches
used
to
set
the
amplifier
configuration.
All
switches
set
to
the
left
position
is
the
standard
configuration.
AUTO
STANDBY-
If
enabled
(ON),
the
amplifier
goes
into
lower-power
mode
after
twenty
minutes
without
an
input
signal.
If
in
lower-power
mode
and
an
audio
signal
is
detected,
the
amplifier
will
automatically
wake
and
amplify
audio
within
1
second
.
The
default
position
is
OFF.
GLOBAL
OUT-
Sets
the
output
capability
to
70V
or
100V
for
all
outputs
that
have
their
OUTPUT
DIP
switch
set
to
Hi-Z.
In
70V
Hi-Z
mode
and
Low-Z
mode,
100
Vpeak
and
70V
RMS
limiters
are
automatically
loaded. In
100V
Hi-Z
mode,
141
Vpeak
and
100V
RMS limiters are
automatically
loaded.
These are
maximum
values
that
can
be
lowered
using
the
PowerShare
Editor
software
if
necessary. See
the
Software
Int
erface
section
for
more
detail
s.
CONFIG
-
In
REAR
mode,
the
rear
pan
el EO
settings
are
all
that
are
required
to
configure
the
amplifier.
In
SOFTWARE
mode,
the
PowerShare
Editor
Software
configures
the
amplifier,
and
the
rear panel EO
switches
are
ignored. See
the
Software
Interface
section
for
more
details.
SENSITIVITY-
Select 4
dBu
or
12
dBu
as
the
amplifier
sensitivity
for
th
e
Euroblock
line-level inputs. The
unbalanced
RCA
input
sensitivity
is
-10
dBV
in
the
4
dBu
sensitivity
setting,
and
-2
dBV
in
the
12
dBu
sensitivity
setting.
OUTPUT 1
-Select
70/100V
high
impedance
output
(Hi-Z)
or
4
-8
0
low
impedance
output
(Low-Z)
for
OUTPUT
1.
OUTPUT 2 -
Select
70/100V
high
imp
e
dance
output
(Hi-Z)
or
4- 8
0
low
imp
eda
nce
output
(Low
-
Z)
for
OUTPUT
2.
0
OUTPUT ATTEN 1
&
2 -
Output
attenuators
for
each
output.
Turn
the
attenuators
clockwise
to
decrease
attenuation,
and
c
ounter-clockwise
to
increase
attenuation.
Fully
clockwise
is
0
dB
attenuation
;
fully
counter-clockwise
is
mute.
If
CC-1
zone
controller(s)
are used,
then
the
CC-1
becomes
the
master
volum
e
control(s).
The
position
of
each
attenuator
will
determine
the
CC-1
zone
c
ontroller
range
for
that
output.
Set
each
trim
to
0
dB
attenuation
to
allow
each
CC-1
zone
controller
to
have full
attenuation
range.
If
the
CC
-1
is
disconn
ected
from
the
a
mplifier
,
th
en
the
output
attenuator
be
come
s
the
a
ctive
setting.
0
OUTPUT
-
Two
inv
e
rted
2-
pin
E
uroblo
ck
connectors
for
lo
udspe
aker
connections. Each channel can
deliver
up
to
600
watts
regardless
of
load
into
4
0,
8
0,
70V
,
or
100V.
Outputs
are
not
bridgeable.
0
AC
Inlet
-
Removing
th
e AC
cord
when
the
amplifier
is
on
is
equivalent
to
powering
down
using
the
front
panel
power
switch,
and
is an
acceptable
power-down
method
.
78 Eng
li
sh Ins
tall
a
ti
on
Guid
e

Other manuals for Bose PowerShare PS602P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bose PowerShare PS602P and is the answer not in the manual?

Bose PowerShare PS602P Specifications

General IconGeneral
BrandBose
ModelPowerShare PS602P
CategoryAmplifier
LanguageEnglish

Related product manuals