45
TAP COMMANDS
12. Set Region Code
12.1 Manufacturing command Prompt, Page
40 Step 1-9.
12.2 Enter “/opt/Bose/mfgdatatool –w region-
code XX” Where XX equals:
• GB – Australia, Hong Kong, UAE, India,
China, Germany, Austria,
Switzerland, Italy, France,
Belgium, Poland, Netherlands,
Denmark, Sweden, Norway,
Finland, UK, Hungary.
• US – USA, Canada, Taiwan, Latin -
America.
• JP – Japan.
13. Set Variant Mode
To set the unit from manufacturing status to
normal status.
13.1 Enter
“/opt/Bose/mfgdatatool –w variantmode nor-
mal”.
14. Software Version
14.1 Tap Command Setup - Procedure 1.
14.2 Enter
”sys ver”
The unit will reply with something similar to the
following:
“BoseApp version: 9.0.41.23338.1383271
epdbuild.trunk.hepdswb1d04.2015-08-
19T15:31:01
15. System Reboot
15.1 Tap Command Setup - Procedure 1.
15.2 Enter “sys reboot” to soft boot the sys-
tem.
16. Factory Default
16.1 Tap Command Setup - Procedure 1.
16.2 Enter “sys factorydefault” to reboot the
system into factory default mode.