TAP COMMANDS CONTINUED
6. Set Serial Number
6.1 Enter Manufacturing Mode (Procedure 3)
6.2 Type
/opt/Bose/mfgdatatool –w sn 1 serial number
Where serial number equals the 17 digit serial
number located on the product’s label.
7. Software Version
7.1 “sys ver”
The unit will reply with something similar to
the following, significant digits are bold:
BoseApp version: 9.0.20.21985.1290890
epdbuild.Release2_2015.hepdswbld05.2015-
06-16T11:50:25
8. Display Test (OLED)
8.1 Enter TAP command ‘local_services on’
8.2 Press Control C and then type ‘e’ and then
enter.
8.3 At the mojo login, enter TAP command
‘root’.
8.4 Enter TAP command ‘cd /opt/Bose’
8.5 At the root@Taigan:Bose prompt, enter
the following TAP commands to display
different sections of the display.
cat oled_pattern_left_bar.raw > /dev/fb
cat oled_pattern_center_bar.raw > /dev/fb
cat oled_pattern_right_bar.raw > /dev/fb
cat oled_pattern_cols.raw > /dev/fb
cat oled_pattern_rows.raw > /dev/fb
cat oled_pattern_outline.raw > /dev/fb
8.6 To return unit to normal mode, Enter TAP
command ‘rm /mnt/nv/local_services’
Enter TAP command ‘sys reboot’
9. Factory Default
9.1 Enter TAP command ‘sys factorydefault’