Do you have a question about the Boss PRO SE-70 and is the answer not in the manual?
Type | Multi-effects processor |
---|---|
Sampling Rate | 44.1 kHz |
Bit Depth | 16-bit |
MIDI | In, Out/Thru |
Effects | Reverb, Delay, Chorus, Flanger, Phaser, Pitch Shifter, Distortion, EQ, Compressor, Noise Gate |
A/D Conversion | 16-bit linear |
D/A Conversion | 16-bit linear |
Frequency Response | 20 Hz - 20 kHz |
Details the 35 effects and 45 algorithms, highlighting sound quality and versatility.
Describes the ability to produce warm and fat analog distortion sounds.
Lists rare vintage effects like Slow Gear, Vibrato, and Ring Modulator.
Explains the 2,000 ms sampling capacity and reverse playback.
Highlights the integrated guitar and bass synthesis feature.
Details the chromatic tuner with string name display and tuning methods.
Describes the metronome's rhythm selection, including 8 beat, 16 beat, shuffle.
Explains control over parameters using foot-switch, expression pedal, or MIDI.
Covers stereo input/output for maintaining stereo image and parallel processing.
Details MIDI connectors for data exchange and sequencing.
Information on mounting the unit in a 19-inch rack using an optional adapter.
Explains how to connect the SE-70, select Patches, and basic procedures.
Introduces MIDI, Patch selection, and control via external MIDI devices.
Provides information for troubleshooting and other useful details.
Guidelines for using the correct power adaptor and safe electrical connections.
Recommendations for unit placement to avoid extreme temperatures or interference.
Instructions for cleaning the unit and avoiding damage from chemicals.
Information about the internal battery and data preservation.
General precautions for handling, impact, and foreign objects.
Overview of the SE-70's front panel controls and indicators.
Overview of the SE-70's rear panel connectors and switches.
How to connect the SE-70 to external devices like mixers and keyboards.
Step-by-step guide for powering on the SE-70 after connections are made.
How to set input levels using knobs and the overload indicators.
Methods for choosing effect presets (Patches) using the panel.
Using optional foot-switches (FS-5U/FS-5L) to change Patches.
How to select Patches remotely using MIDI Program Change messages.
Methods for activating or bypassing effects using the panel or foot-switches.
Using MIDI messages to turn effects on or off.
Configuring the unit's output when effects are turned off (Direct or Mute).
Understanding Patches, User Areas, Presets, and Algorithms.
Initial steps for editing existing Patches to create new ones.
Adjusting effect parameters to modify the sound of a Patch.
Assigning a custom name (up to 12 characters) to a modified Patch.
Saving edited Patch settings into memory using the Write procedure.
Duplicating Patch data from one location to another.
Detailed steps for modifying effect parameters within a selected Patch.
Renaming user-created Patches to avoid confusion.
Saving all changes made to a Patch into memory permanently.
How to use the built-in chromatic tuner for guitars, basses, and other instruments.
Playing notes and using tuning guides to achieve accurate pitch.
Configuring tuner type (Guitar, Bass, Others).
Adjusting the standard pitch frequency (A=440Hz) for tuning.
Displaying string names and selecting tuning methods (Regular, Flat, Double-Flat).
Adjusting the audio level for the tuner function.
Configuring the metronome's rhythm, tempo, volume, and level.
Assigning functions to the EFFECT REMOTE/EXP PEDAL jack.
Configuring functions for pedals connected to the CONTROL 2/3 jacks.
Modifying the LCD brightness for better readability.
Setting up external controllers (pedals, MIDI) to manipulate parameters.
Explanation of MIDI connectors (IN, OUT, THRU) and MIDI cables.
Understanding MIDI channels for transmitting performance information.
Overview of MIDI message types processed by the SE-70.
How Aftertouch messages control parameters.
Using Pitch Bend messages for parameter control.
How Program Change messages select Patches.
Using Control Change messages for performance expression.
Handling device-specific data for saving or transferring settings.
A reference chart for MIDI message compatibility and handling.
Configuring the MIDI channel and Omni mode for communication.
Remotely selecting Patches using external MIDI units.
Customizing the correspondence between MIDI Program Change and Patch numbers.
Setting up MIDI messages to control parameters in real-time.
Connecting and using the BOSS FC-50 MIDI foot controller.
Transferring Patch data using Exclusive messages (Bulk Dump/Load).
Configuring MIDI OUT/THRU connector settings.
Procedure for sending SE-70 data to external devices.
Procedure for receiving data from external devices into the SE-70.
Connecting and using the SE-70 with a keyboard controller and sound module.
Connecting the SE-70 with a guitar and amplifier, plus foot controllers.
Connecting the SE-70 to a sequencer for automatic Patch changes.
Details on the default system data and preset configurations.
How to reset the SE-70 to its original factory default settings.
Troubleshooting steps for issues with no sound or low output level.
Diagnosing problems related to the overload indicators.
Resolving issues when the CONTROL knob doesn't change the Patch Number.
Troubleshooting the Patch saving (Write) operation.
Fixing issues with foot-switch controlled Patch number changes.
Steps to take when the SE-70 does not receive MIDI data.
Troubleshooting MIDI Program Change message reception.
Resolving problems with MIDI control over parameters.