24
M21-M26-M30
6. Operation 6.
6.1.12 Opening the Loading Door
Never leave the loading door standing open!
Before each start, make sure that the loading door is closed.
During longer standstills, concentrations of the solvent gas can form.
You can unlock the loading door with the button for up to 10 minutes.
Starting with the 11
th
minute, you cannot open the loading door until after you have started the
"DEODORIZING" program (P43) and the horn has stopped sounding.
Once the machine has been turned on, it is not possible to open the loading door until the
"DEODORIZING" program (P43) starts and the horn sounds to signal the end of the program.
Attention: When neither current nor compressed air is present or
when the program has been interrupted, a mechanical
EMERGENCY opening is possible with the help of a tool.
The trained user is permitted to carry out an EMERGENCY opening only when the program has stopped
and the cage is not turning. Before the emergency opening, carefully open the button trap cover in order
to release any overpressure.
After removing garments that have not finished drying, place them in a solvent-tight transport container.
Obey the safety regulations.
Emergency release:
707760-04-0
Unlock by pushing the pin (1) down.
Open the loading door at the same time (2+3).
After correcting the error, close the loading door and cover and continue the program by pressing the