3000
OWNERS MANUAL
Premier Series
Non-Programmable
Single Stage Heat/Cool
Digital Thermostat
Compatible with low voltage single stage gas,
oil or electric heating or cooling systems,
including single stage heat pumps. This
thermostat can also be used on 250mv to
750mv millivolt heating only systems. Do not
use this thermostat on applications with
voltages above 30 Volts AC.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
© 2004 Braeburn Systems LLC All Rights Reserved. Pub. No. 3000-100-002
Store this
booklet for
future reference
WARRANTY
YEAR
LIMITED
CONTENTS
WARNING!
Important Safety Information
FEATURES
SPECIFICATIONS
INSTALLATION
Replacing Existing Thermostat
Installing Your New Therm ostat
TESTING YOUR NEW THERMOSTAT
PROGRAMMING USER SETTINGS
Default Thermostat Settings
Setting Temperature Dif ferential
ADDITIONAL OPERATION FEATURES
Review Set Temperature
Changing Set Temperature
High Te mperature Safety Switch
Low Temperature "Freeze" Protection
Compressor Protection Feature
Changing Fahrenheit (˚F) to Celsius (˚C)
Low Battery Detection and Replacement
Replacing the Batteri es
Resetting Thermostat
TROUBLESHOOTING
WIRING DIAGRAMS
1
2
3
4
5
6
7
8
5.1
3.1
3.2
5.2
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.7.1
• Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating this
thermostat.
•
This thermostat is designed for use with a 24 Volt-AC low voltage single stage gas,
oil or electric heating or cooling systems, including single stage heat pumps. This
thermostat can also be used on 250mv to 750mv millivolt heating only systems.
• Do not use this thermostat on a pplications with voltages above 30 Volts AC.
• This thermostat requires two (2) properly installed "AA" alkaline batteries to
provide power for the thermostat to properly control the system operation.
•
The system must have 24 Volt AC power present for proper system operation and control.
• Wiring must conform to all building codes and ordinances as required by local and
national code authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could
damage the thermostat and void the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F
(10˚ C). This could possibly damage the controlled cooling system and may cause
personal injury.
• This thermostat should only be used as described in this manual. Any other use is
not recommended and will void the warranty.
1