EasyManua.ls Logo

Braeburn 3220 - Operating Your Thermostat; Setting the System Control Mode

Braeburn 3220
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTRUCTIONS
TheInstallerSettingsmustbeproperlyconguredinorderforthisthermostattooperatecorrectly.TheInstaller
Settingsaremenudriven.Theportionofthesesettingsthatdonotapplytoyoursetupwillbeskipped.These
settingsareindicatedbelowwithcomments.Moredetailoneachsettingfollowsthistable.
1. PressandholddowntheRETURNand
buttonsfor3seconds.
2. Releasebothbuttonsandtherstinstaller
settingwillbedisplayed.
3. Changesettingsasrequiredusingthe
orportionoftheSpeedBar
®
.
4. PressNEXTorBACKtomovetothenext
orprevioussetting,pressRETURNtoexit.
No. Installer Setting Factory Setting Comments
(
Notes follow this table) Default Options (More information follows this table)
1 TemperatureScale F DEG F DEG SelectforFahrenheitdisplay
C DEG SelectforCelsiusdisplay
2 AutoChangeover oF AUTO oF AUTO DisablesAutoChangeovermode
ON AUTO EnablesAutoChangeovermode
11CONV Selectfor1H/1CConventionalsystem
22CONV Selectfor2H/2CConventionalsystem
3 SystemType 11CONV 11HP Selectfor1H/1CHeatPumpsystem
22HP Selectfor2H/2CHeatPumpsystem
32HP Selectfor3H/2CHeatPumpsystem
1HD SelectforHeatOnlyHydronicsystem
11HD SelectforHydronicHeat/1Csystem
4 1stStageDifferential 0.5 DIF1 0.5, 1.0or Selecta1ststagetemperaturedifferentialof.5°,
2.0 DIF1 1°or2°F(0.2°,0.5°or1°C)
5 2ndStageDifferential 2.0 DIF2 1.0, 2.0, 3.0, Selecta2ndstagetemperaturedifferentialof1°,
[note 1] 4.0, 5.0or 2°,3°,4°,5°or6°F(0.5°,1°,1.5°,2°,2.5°or3°C)
6.0 DIF2
6 3rdStageDifferential 2.0 DIF3 1.0, 2.0, 3.0, Selecta3rdstagetemperaturedifferentialof1°,2°,
[note 1] 4.0, 5.0or
3°,4°,5°or6°F(0.5°,1°,1.5°,2°,2.5°or3°C)
6.0 DIF3
7 1stStageFanControl HG FAN 1 HG FAN 1 Selectfor1ststageGasheating
[note 2] HE FAN 1 Selectfor1ststageElectricheating
8 EmergencyHeat] HE EMER HE EMER SelectforElectricEmergencyHeat
FanControl[note 3] HG EMER SelectforGasEmergencyHeat
9 ReversingValve REVO REVO SelectforcoolactiveReversingValve(Oterminal)
(O/BTerminal)[note 4] REVB SelectforheatactiveReversingValve(Bterminal)
10 FossilFuel AE AUX AE AUX SelectforElectricAuxiliaryheat(withcompressor)
BackupHeat[note 3] AG AUX SelectforGasAuxiliaryheat(withoutcompressor)
4
Installer Settings
9 Installer Guide
NOTE: Shaded areas below do not apply to the 3020.