cont.
Wiring Diagrams
7
R O
Reversing Valve
(Active in Cooling
- See NOTE 3)
B Y1
G W2
Transformer Common
(See NOTE 1)
1st Stage
Compressor
Contact
Emergency
Heat Control
2nd Stage
Heat Control
Fan Control
24 VAC
Hot
120 VAC
Neutral
See NOTE 2
MODEL 1200, 1200NC: Multi-Stage Heat Pump Systems
NOTES: 1. Transformer common not required for battery-only operation of
thermostat. 2. Jumper is required to use Auxiliary Heat for both Second Stage and
Emergency Heat on units without separate Emergency Heat and Auxiliary Heat terminals.
3. For units requiring reversing valve to be energized during heating, connect reversing
valve to B terminal. For units requiring reversing valve to be energized during cooling,
connect reversing valve to O terminal.
Reversing Valve
(Active in Heating
- See NOTE 3)
C E/W1
(See NOTE)
Transformer Common
R Y1 E/W1 W2GO B C
1st Stage
Compressor
Control
1st Stage
Heat Control
Fan
Control
2nd Stage
Heat Control
24 VAC
Neutral
120 VAC
Hot
MODEL 1200, 1200NC: Conventional Systems (Single Transformer)
NOTE: Transformer common not required for battery-only operation of thermostat.
10
STORE THIS BOOKLET FOR FUTURE REFERENCE
©2004 Braeburn Systems LLC • Patents Pending • All Rights Reserved Made in China
•
No. 1000-100-009
This warranty gives you specific legal rights and you may also have other rights that vary from
state to state or province to province. Answers to any questions regarding our limited warranty
may be obtained by writing our corporate offices.
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
WARRANTY FACILITY: Braeburn Systems LLC
Attn: Warranty Department
2215 Cornell Avenue
Montgomery, IL 60538
MODEL 1000, 1200: 5 YEAR LIMITED WARRANTY
MODEL 1000NC, 1200NC: 2 YEAR LIMITED WARRANTY
Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are
due to faulty material or workmanship. This warranty and our liability does not apply to
batteries, nor does it include damage to merchandise or the thermostat resulting from
accident, alteration, neglect, misuse, improper installation or any other failure to follow
Braeburn installation and operating instructions. This limited warranty applies for the duration
of the warranty period from the original date of purchase by a professional service technician.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under
warranty provided it is returned postage prepaid to our warranty facility in a padded carton
within the warranty period, with proof of the original date of purchase and a brief description
of the malfunction. This limited warranty does not include the cost of removal or
re-installation.
LIMITED
WARRANTY
1000 Series