Only use approved chargers with the fridge battery, incorrect chargers may result in
fire, damage, a shortened battery life. Do not disassemble, impact, squeeze, crush, or
throw or misuse the fridge battery, do not dispose of in fire, any of which may result in
short circuit and fire or explosion. If there is swelling and heating of the fridge battery
do not continue to use, it may result in fire or explosion, do not use the battery if it is
wet or damp.
Battery Operation
Long press on the battery to switch
ON/OFF the battery
Tips to make the battery last longer:
1. Switch to ECO mode by pressing
on the fridge panel;
2. Set the battery protection to “L” mode
(very important setting to make the
battery work longer time)
3. Pre-chill the fridge to your ideal
temperature in advance;
4. Do not open the door frequently;
5. Do not set the temperature too low if not necessary.
WARNING: Do not open or disassemble the battery.
WARNING: Do not charge fridge / freezer with DC 12V and Solar Panel at the same time!
The fridge could be seriously damaged and pose a potential hazard to you.
Solar Panel Charge Connection
Insert the solar charge cable into the
refrigerator’s Solar charge interface
Max Solar input Voltage: 50V
Max Solar input Current: 10A
Checking Charge Status: When the
refrigerator is powered
ON and DC / AC power is connected, the
battery icon on display screen will flash to
show charging. To charge the fridge / freezer battery without running the compressor,
simply connect the adapters without powering “ON” the fridge. To view charging status
please press and hold button for 3 seconds. The fridge’s battery status and voltage
will be displayed. When the voltage reaches 12.6V and the battery icon stops flashing,
the unit has been fully charged and wiring should be disconnected to prevent internal
component from damage.