Brilix XHPFDPLUS60 - Parameter Settings (0-8)

Brilix XHPFDPLUS60
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter 2
Total working time of compressor
after frosting (30-90 min,default
setting : 40 min)
Parameter 5
Time of Exit defrosting (1 to 12
min, default setting 12 min)
Parameter 8
Heating target for superheat
(-15 °C-15 °C) default
setting: 3 °C
Parameter 1
To set the entering water temp.
under heating mode (15-40 °C,
default setting:28 °C)
Parameter 4
Terms of Exit defrosting
function (2 to 30 °C, default
setting 20 °C)
Parameter 7
Mode selection of Electronic
expansion valve ( 0 to 1),
default setting 1 (auto)
Parameter 0
To set the entering water temp.
under cooling mode (15-35 °C,
default setting: 28 °C)
Parameter 3
Terms of Entry defrosting
function (-30 °C to 0 °C, default
setting -7 °C)
Parameter 6
Mode : 0 Cool 1 Heat and
Cool 2 Heat and cool + auxiliary
elec. Heating 3 Heat default
setting: 1 Heat and Cool
Remarks:
For the XHP series ,
Mode default setting : 3. Heat