BHS-4000A
Installation
and
Programming
Instructions
Blinking
LED
Message
Correction
3
Trouble
on
fire
zone.
If
the
trouble
follows
a
canceled
fire
alarm,
allow
time
for
any
smoke
particles
to
disperse.
Replace
the
detector,
if
necessary.
4
Call
Brink’s
at
1
(800)
445-0872.
Call
Brink’s
Customer
Care.
5
Device
supervisory
problem.
A
wiring
problem
exists.
Verify
the
wire
connections.
Replace
any
defective
wires.
Replace
device
or
panel,
as
necessary.
6
Siren
supervisory
failure.
A
wiring
problem
exists.
Verify
the
wire
connections.
Replace
any
defective
wires.
Replace
siren
or
panel,
as
necessary.
8
Line
cut.
The
telephone
line
has
been
cut,
or
service
is
interrupted.
Hang
up
all
telephones.
If
the
telephone
service
is
interrupted,
instruct
the
customer
to
call
the
telephone
company.
To
identify
whether
the
ninth
condition
exists,
press
the
OPTIONS
+
9
keys
again.
If
the
zone
LED
1
is
lit,
a
Host
failure
has
occurred.
1
Host
failure.
The
control
panel
could
not
complete
a
call
to
the
Downloaded
Verify
the
telephone
service
is
working.
Verify
the
panel
programming.
Verify
wiring
connections.
Replace
any
defective
wires.
Replace
control
panel,
if
necessary.
2
AC
Failure.
The
AC
power
to
the
panel
is
interrupted.
Check
to
ensure
the
panel
is
plugged
in.
Check
for
broken
or
loose
wires.
Is
power
out
in
the
rest
of
the
house?
If
not,
check
the
circuit
breaker.
If
AC
is
present
across
terminal
1
and
2,
then
replace
control
panel.