BHS-4000A
Installation
and
Programming
Instructions
Panel
Bell
-
K;
.
235D$UP-panei-AB
12M
Wiring
2350-SUP,
BHS-4000A
and
AB-12M
3.10
Wire
the
BHS-3250
Receiver
Refer
to
the
BHS-3250
Installation
Instructions
P/N
K0982
for
more
information.
To
wire
the
receiver,
do
the
following:
1.
Disconnect
the
system’s
AC
and
DC
power.
2.
Wire
the
receiver
according
to
the
table
and
illustrations.
Relay
(N.O.)
Switched
EARTH
SIREN
AUX
CLK
DATA
RHS325€-P^n$i-
Wire
the
receiver
to
the
panel
3.10.1
W
ire
Relay
and
Switched
12V/100mA
Output
The
receiver
has
a
24
V,
0.5
A
(form
A)
reed
relay,
and
a
transistor
switched
12V/100mA
output,
for
control
of
external
devices.
Wire
the
relay
terminals
in
the
same
manner
that
you
would
connect
a
norm
ally-open
switch.
Wire
the
12V/100mA
switched
output
as
required;
OUT2
is
the
+12V
output
and
C
is
the
return.
For
additional
information
regarding
mounting
and
wiring,
refer
to
the
BHS-3250
Receiver
installation
instructions.
3.11Connect
to
AC
power
3.11.1
W
ire
the
transformer
The
BHS-4000A
uses
a
16.5
VAC,
25
VA
or
40
VA
transformer
(See
Section
6.1.2
for
a
list
of
approved
models.)
Connect
the
power
terminals
of
the
transformer
to
the
AC
terminals
on
the
main
PCB,
as
shown
in
the
following
diagram.
Note:
Connect
the
transformer
using
18
AWG
or
larger
and
do
not
exceed
a
wire
length
of
more
than
100
feet.
I
I
I
\
Wire
the
transformer
3.11.2
C
onnect
to
Earth-Ground
An
Earth-ground
connection
protects
the
system
from
damage
caused
by
power
surges.
For
the
most
effective
protection,
a
“unified
Earth-ground”
is
recommended.
A
unified
Earth-ground
provides
a
common
ground
to
the
power
and
telephone
lines,
and
the
security
system.
To
create
an
Earth-ground
connection,
run
a
14-gauge
solid
copper
wire
from
terminal
5
(Earth)
to
the
central
terminal
(Ground)
of
the
transformer,
if
the
terminal
is
available.
If
your
transformer
does
not
have
an
Earth
Ground
terminal,
you
can
create
a
Unified
Earth
Ground
connection
as
shown
in
the
following
illustration.
Unified
Earth-Ground
Unified
Earth-ground
connection
3.12
Connect
the
backup
battery
The
BHS-4000A
uses
a
Premier
or
Universal
Brand
12
VDC
lead-
acid
backup
battery
(see
section
6.1.2).
Choose
either
a
4
Ah
or
a
7
Ah
model.
To
determine
the
proper
Ah
rating
for
the
battery,
refer
to
the
Battery
Loading
Chart
in
Section
3.13.
To
connect
the
backup
battery,
do
the
following:
1.
Connect
the
red
lead
to
the
battery’s
positive
terminal.
2.
Connect
the
black
lead
to
the
battery’s
negative
terminal.
Mounting
and
connecting
the
battery