Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
89
Trident Water Management System
(cont.)
Trident Test Procedure & Service Checks
(cont.)
Service Checks
Check the water inlet solenoid is energised.
Check the water supply stop tap is turned ON.
Check the water inlet solenoid operates.
Check the water inlet solenoid and supply hose filters are not blocked.
Check if the pump operates when powered ON and delivers sufficient water to the
distribution system.
Check the water distribution system is not blocked.
Check the filter pads are in good condition and not damaged.
Check if low evaporation rate conditions have applied.
Check if the ServoSeal opens and the drain valve is closes fully.
Check if the ServoSeal closes and the drain valve opens fully.
Check for coating on the sensor probe which may prevent proper circuit.
Check if the sensor probe wiring and terminals are open circuit.
Check if the sensor probe wiring and terminals are short circuit.
Check the N-E5 internal 8 Amp fuse is not open circuit.
Check the N-E5 module is located correctly in the base terminal connection
mounting bracket.
Check the Trident loom and plug connections.
Check in the N-E5 is a 10 Volt output to the water inlet solenoid in the OFF cycle.
Check the water inlet pressure is within 300 - 1000 kPa.