EasyManua.ls Logo

Brivo B-ACS-SDC-E - Verify Shipping Contents

Brivo B-ACS-SDC-E
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2023 Brivo Systems LLC. All rights reserved. PUB-Brivo ACS-SDC-E Installation Manual_v1.2
7
Brivo ACS-SDC-E Installation Manual
Verify shipping contents
1. Locate and check the contents of the Control Panel kit.
The ACS-SDC-E kit should contain the following parts:
a) 1 cardboard box containing the following:
· The B-ACS-SDC-E unit, with its identication label on the back
· An additional loose label for reference
· A quick start guide
· A bag of accessory parts containing:
· One MOV (Metal Oxide Varistor)
· Two 120 ohm RS485 bus termination resistors.
· Six 2k ohm end-of-line (EOL) tamper termination resistors
· One cover plate for a single gang electrical junction box
· One strain relief zip tie for Ethernet cable
Plan your installation and decide where to install the ACS-SDC-E
1. If not using Power over Ethernet (PoE), do not place the ACS-SDC-E more than 100 feet from the
12V DC power supply transformer. This is the maximum cable run allowed by most external power
supplies.
a) The ACS-SDC-E does not specify a maximum wiring length between the ACS-SDC-E and a
reader, but the keypad/reader manufacturer may. Follow manufacturer guidelines for wiring
type and distance between controller and reader.
b) Place the ACS-SDC-E within 500 feet of its associated electronic strike or latch.

Related product manuals