Brivo ACS-SDC-E Installation Manual
4. Optionally, you may use PoE and an external 12V power supply for redundant simultaneous power
input.
LED behavior for the ACS-SDC-E
The ACS-SDC-E unit has ve LEDs with the following colors and functions:
1. Power - [GREEN]
2. Network Link - [GREEN]
3. LED3 [RED] : OSDP Reader State Blink / Factory Reset
4. LED2 [GREEN] : PCS Connection Solid ON/OFF
5. LED1 [BLUE] : Heartbeat Blink
Resetting the ACS-SDC-E to factory default
The ACS-SDC-E unit goes into a factory default reset sequence when the following steps are performed:
1. Press and hold the factory default reset (FDR) button for ten (10) seconds and wait for the solid red
LED to light up and stay solid.
2. Release the button within three (3) seconds.
3. After releasing the button, the ACS-SDC-E unit will recognize that a factory reset is desired and will
initiate the factory default reset procedure. As the ACS-SDC-E unit restarts, the rmware will
automatically update. Once LED operation returns to normal, the ACS-SDC-E unit will have been
reset.
NOTE: If the Factory Default Reset (FDR) button is released after 13 seconds or more than three seconds
after the red LED is solid, a factory reset will not occur.